NAME Jariakin Mekanikako Laboratorioa

DESCRIPTION

Dituen ekipoengatik eta diziplina anitzeko taldea izanik, osasun sektorerako mikro eta makro gailuak eta prozesuak garatzeko gai dira. Konputazio ahalmenari esker, gailuen portaera fluidikoa azter dazeketa, geometria eta prozesua optimizatuz. Laginak karakterizatzeko, zenbakizko simulazio konplexuak egiteko (fase anitzekoak, osagai anitzekoak, fluido-egitura elkarreragina, etab.), geometria , prozesuak optimizatzeko, entsegu bankuen eraikuntza ondorengo baliozkotzea ahalbidetzeko gai dira.

FIELDS OF APPLICATION

Biomedical consumables

In-Vitro diagnostics

Laboratory equipment

MOST OUTSTANDING EQUIPMENT AND COMPONENTS

  • Anton Paar MCR 501 Reometroa

    Minimum torque: 0.1 µNm
    Maximum torque: 230 mNm
    Torque resolution: 0.001 µNm
    Torque accuracy max.: 0.2 µNm; 0.5%
    Maximum rise of torque 1500 Nm,s
    Speed range CSS: 10-7 min-1 - 3000 min-1
    Speed range CSR: 10-6 min-1 - 3000 min-1
    Typical adjustment time: to a speed of 1000 min-1: 150 ms

  • Computational Cluster (Ansys Campus Licence)

    150 nodes
    10 WorkStations
    50 Research Licences

  • DMA 5000M Anton Para Densimeter

    Density Measuring Range: 0 g,cm3 to 3 g,cm3
    Density Accuracy: ±0.000005 g,cm3
    Density Repeatability: 0.0000001 g,cm3
    Minimum Sample Volume: 1ml
    Temperature Range: 0 °C to 90 °C
    Temperature Accuracy: ±0.01 °C
    Temperature Repeatability: 0.001 °C
    Pressure Range: 0 bar to 10 bar

  • Laser CO2 FL-1409

    Total dimensions - 1920x1495x1025mm
    Laser type - CO2 water-cooled glass tube
    Engraving speed - 1000 mm,sec
    Cutting speed - 680 mm,sec
    Repetition accuracy - ±0.02mm

  • Litesizer™ 500 Particle Analyzer

    Particle size specifications
    Measuring range: 0.3 nm–10 μm* (particle diameter)
    Minimum sample volume: 12 µL
    Sensitivity
    Min. concentration: 0.1 mg,mL (lysozyme)
    Max. concentration: 50 %m,v (sample-dependent)
    Accuracy Better than: +,-2 % on NIST traceable standards
    Repeatability Better than: +,-2 % on NIST traceable standards
    Measurement angles: 15°, 90°, 175°

    Zeta potential specifications
    Measuring range: >= +,- 1000 mV
    Mobility range: 10 -11 m²,V.s to 2 x 10 -7 m²,V.s
    Size range: 3.8 nm–100 µm
    Min. sample volume: 50 µL (sample viscosity dependent)
    Sensitivity: 0.1 mg,mL (lysozyme)
    Maximum sample concentration: 70 %w,v
    Accuracy : +,- 10 %
    Repeatability: +,- 3 %
    Maximum sample conductivity: 200 mS,cm

    Molecular mass specifications
    Measuring range (mass): 980 Da–20 MDa
    Measuring range (particle size): up to 40 nm (diameter)
    Lowest concentration limit: 0.1 mg,mL (lysozyme)
    Accuracy: +,-10 %
    Repeatability: +,-5 %
    Measurement angle: 90°

    Transmittance specifications
    Accuracy Better than: +,-1 %
    Measuring time: 10 s
    Minimum sample volume: 15 µL

    Refractive index specifications
    Measuring range: 1.28 to 1.50
    Accuracy: +,-0.5 %
    Minimum sample volume: 1 mL

SERVICES OFFERED BY THE ASSET

CFD Simulations

Numerical simulations to optimize geometries or processes in fluidic devices

Manufacturing of Fluid Devices

Manufacture of fluidic devices by laser cutting

Sample Characterization

Determine thermophysical properties (density, viscosity, thermal and mass expansion and refractive index) -Characterization of colloidal samples between 10 microns and 0.3 nm (size and concentration distribution)