Search
back to search
NAME

Jariakin Mekanikako Laboratorioa

DESCRIPTION

Dituen ekipoengatik eta diziplina anitzeko taldea izanik, osasun sektorerako mikro eta makro gailuak eta prozesuak garatzeko gai dira. Konputazio ahalmenari esker, gailuen portaera fluidikoa azter dazeketa, geometria eta prozesua optimizatuz. Laginak karakterizatzeko, zenbakizko simulazio konplexuak egiteko (fase anitzekoak, osagai anitzekoak, fluido-egitura elkarreragina, etab.), geometria , prozesuak optimizatzeko, entsegu bankuen eraikuntza ondorengo baliozkotzea ahalbidetzeko gai dira.

MOST OUTSTANDING EQUIPMENT AND COMPONENTS

Minimum torque: 0.1 µNm
Maximum torque: 230 mNm
Torque resolution: 0.001 µNm
Torque accuracy max.: 0.2 µNm; 0.5%
Maximum rise of torque 1500 Nm,s
Speed range CSS: 10-7 min-1 - 3000 min-1
Speed range CSR: 10-6 min-1 - 3000 min-1
Typical adjustment time: to a speed of 1000 min-1: 150 ms

150 nodes
10 WorkStations
50 Research Licences

Density Measuring Range: 0 g,cm3 to 3 g,cm3
Density Accuracy: ±0.000005 g,cm3
Density Repeatability: 0.0000001 g,cm3
Minimum Sample Volume: 1ml
Temperature Range: 0 °C to 90 °C
Temperature Accuracy: ±0.01 °C
Temperature Repeatability: 0.001 °C
Pressure Range: 0 bar to 10 bar

Total dimensions - 1920x1495x1025mm
Laser type - CO2 water-cooled glass tube
Engraving speed - 1000 mm,sec
Cutting speed - 680 mm,sec
Repetition accuracy - ±0.02mm

Particle size specifications
Measuring range: 0.3 nm–10 μm* (particle diameter)
Minimum sample volume: 12 µL
Sensitivity
Min. concentration: 0.1 mg,mL (lysozyme)
Max. concentration: 50 %m,v (sample-dependent)
Accuracy Better than: +,-2 % on NIST traceable standards
Repeatability Better than: +,-2 % on NIST traceable standards
Measurement angles: 15°, 90°, 175°

Zeta potential specifications
Measuring range: >= +,- 1000 mV
Mobility range: 10 -11 m²,V.s to 2 x 10 -7 m²,V.s
Size range: 3.8 nm–100 µm
Min. sample volume: 50 µL (sample viscosity dependent)
Sensitivity: 0.1 mg,mL (lysozyme)
Maximum sample concentration: 70 %w,v
Accuracy : +,- 10 %
Repeatability: +,- 3 %
Maximum sample conductivity: 200 mS,cm

Molecular mass specifications
Measuring range (mass): 980 Da–20 MDa
Measuring range (particle size): up to 40 nm (diameter)
Lowest concentration limit: 0.1 mg,mL (lysozyme)
Accuracy: +,-10 %
Repeatability: +,-5 %
Measurement angle: 90°

Transmittance specifications
Accuracy Better than: +,-1 %
Measuring time: 10 s
Minimum sample volume: 15 µL

Refractive index specifications
Measuring range: 1.28 to 1.50
Accuracy: +,-0.5 %
Minimum sample volume: 1 mL

SERVICES OFFERED BY THE ASSET

services book icon
757

CFD Simulations

services book icon
758

Manufacturing of Fluid Devices

services book icon
756

Sample Characterization

ENTITY MANAGING THE ASSET

Mondragón Goi Eskola Politeknikoa JMA SCoop

Contact person: Unai Ayala

Other related assets

Tell us about your need

Let us get to know you better. If you are looking to implement intelligent technologies and advanced materials that improve the efficiency of your company's production system to offer solutions with more added value, fill in this form.

Scroll To Top